gototopgototop

常見問題

 

alt1. 胸腔成像應用

alt

  

alt2. 工業應用成像

alt  

alt3. 獸醫成像應用

  alt

 

alt4. What is X-Ray?

  X-radiation (composed of X-rays) is a form of electromagnetic radiation. Most X-rays have a wavelength in the range of 0.01 to 10 nanometers, corresponding to frequencies in the range 30 petahertz to 30 exahertz (3×1016 Hz to 3×1019 Hz) and energies in the range 100 eV to 100 keV. X-ray wavelengths are shorter than those of UV rays and typically longer than those of gamma rays. In many languages, X-radiation is referred to with terms meaning Röntgen radiation, after Wilhelm Röntgen, who is usually credited as its discoverer, and who had named it X-radiation to signify an unknown type of radiation. Spelling of X-ray(s) in the English language includes the variants x-ray(s), xray(s) and X ray(s).

 

  X射線(英語:X-ray),又被稱為艾克斯射線、倫琴射線或X射線,是一種波長範圍在0.01奈米到10奈米之間(對應頻率範圍30 PHz到30EHz)的電磁輻射形式。X射線最初用於醫學成像診斷和X射線結晶學。

 

 

alt5. What is scintillator?

 

alt  A scintillator is a material that the property of luminescence when excited by ionizing radiation. Luminescent materials, when struck by an incoming particle, absorb its energy and scintillate. And hence the wavelength of the emitted optical photon: delayed fluorescence or phosphorescence, also called after-glow.

閃爍體就是把 X-ray 轉換為「可見光」的產品,即是將 X-ray 轉換成 PIN TFT / CCD / CMOS 能偵測到之光波段。

alt6. 閃爍體 (Scintillator) 材質及優缺點

 

Item
VT Hamamatsu Others Analysis
聚光型閃爍體技術 創新專利與技術 傳統型
閃爍體
傳統型
閃爍體
VT 的創新專利與技術可進行聚光功能,能有效降低 X-ray 劑量之使用。
環境汙染人體危害 無毒 劇毒 劇毒 VT 獨創新型閃爍體,其使用之材質是無毒成份。
閃爍體材質與應用限制 複合配方 CsI: Tl Gd2O2S:Tb
 / CsI: Tl
目前 VT 採用的聚光型閃爍體技術,可採用任何一種材質,不受制於晶體結構,可進行「長輝、短輝、高亮度」材質組合 、甚至是 X-ray 之外的應用面。
發光效率 > 16% 12% 12% VT 的閃爍體採用複合式配方,發光效率可以超過傳統型閃爍體,有效降低 X-Ray劑量。
漏光率(%) Crosstalk < 0.03%

> 25%

> 25% VT 的閃爍體美國專利製程幾近無漏光,有效降低 X-Ray劑量。

alt7. What is focal spot?

  The area on the anode of an x-ray tube or the target of an accelerator that is struck by electrons and from which the resulting x-rays are emitted. The shape and size of a focal spot influence the resolution of a radiographic image. An increase in focal spot size, which may accompany deterioration of the x-ray tube, reduces the ability to define small structures. Also called actual focal spot.
  X 光管上的靶材,受到電子撞擊,可以產生 X 光的區域。此區域的形狀及大小會影響 X光 成像的分辨率。放大此區域的尺寸會導致「 X 光影像劣化」及「限制了放大倍率」的能力。 此區域也稱為實際撞擊點 (Focal Spot)。

alt8. 常用 X-Ray 的規格

項  目 規  格
管電流 200µA ~ 10mA
管電壓 10kVp ~ 150kVp
Focal Spot 30µm ~ 800 µm
發射角 18° ~ 130°

alt9. 目前 X-Ray Detector (DR) 業界主流設計

項  目 醫療應用 工業、食品、農業應用 獸醫應用
CCD 取像 O **
PIN on TFT 平板 O
CMOS 陣列平板 O
備  註     CR 為主流
▲:部份使用  O:主流應用  ╳:尚無此應用
** 本公司是業界第一家 獸醫 DR 製造公司

alt10. CR 及 DR 的差異比較

項 目 CR
(Computed Radiography)

 

DR
(Digital Radiography)
 

原 理   利用存儲螢光體成像,即IP板吸收X線資訊,IP板感光形成潛影,再經過掃描轉化成數位化信號進入電腦系統進行圖像處理。
  圖像資訊經過讀出裝顯讀出後,存儲在IP板上的信息消失,成像板又可以再重複使用。
     將 X 線信號轉變為可見光通過光電二極體組成的薄膜層(TFT / CCD / CMOS)進行聚集,由專門的讀出電路 直接讀出送交電腦系統進行處理之工作原理。
優 點 成本較低 1. 可得到即時影像,不需另外後製的工作時間
2. 可得到較佳的數位影像品質
缺 點 1.  影像經過一次轉換,成像品質較差,易造成誤判情形。
2.  影像後製時間較長,一般需要數小時之後才能得到 X 光影像。
初期成本較高

alt11. X-Ray 防護規範

  為符合國人之國情,本公司設計之輻射防護,一律設定為背景值(零檢出)之設計。

  原能會之規格為:距機殼 5cm 之檢出輻射計量值 < 0.5uSv。